xtd 0.2.0
Loading...
Searching...
No Matches
xtd::diagnostics::process Class Referencefinal
Inheritance diagram for xtd::diagnostics::process:
xtd::object

Definition

Provides access to local and remote processes and enables you to start and stop local system processes.

class core_export_ process final : public xtd::object
Provides access to local and remote processes and enables you to start and stop local system processe...
Definition process.h:49
Supports all classes in the xtd class hierarchy and provides low-level services to derived classes....
Definition object.h:42
#define core_export_
Define shared library export.
Definition core_export.h:13
Inheritance
xtd::objectxtd::diagnostics::process
Header
#include <xtd/diagnostics/process>
Namespace
xtd::diagnostics
Library
xtd.core

The following example populates a StartInfo with the file to execute, the action performed on it and whether it should displays a user interface. For additional examples, refer to the reference pages for properties of the ProcessStartInfo class.

#include <xtd/diagnostics/process>
#include <xtd/block_scope>
#include <xtd/console>
using namespace xtd;
using namespace xtd::diagnostics;
auto main() -> int {
try {
block_scope_(auto my_process = process {}) {
my_process.start_info().use_shell_execute(false);
// You can start any process other guidgen.
my_process.start_info().file_name("guidgen");
my_process.start_info().create_no_window(true);
my_process.start();
// This code assumes the process you are starting will terminate itself.
// Given that it is started without a window so you cannot terminate it
// on the desktop, it must terminate itself or you can do it programmatically
// from this application using the kill method.
}
} catch (const std::exception& e) {
}
}
// This code can produce the following output :
//
// 1549cf47-b1c9-4333-96e5-4eabffbd9fbd
static void write_line()
Writes the current line terminator to the standard output stream using the specified format informati...
#define block_scope_(...)
The specified expression is cleared automatically when the scope is ended.
Definition block_scope.h:25
@ e
The E key.
The xtd::diagnostics namespace provides classes that allow you to interact with system processes,...
Definition assert_dialog_result.h:10
The xtd namespace contains all fundamental classes to access Hardware, Os, System,...
Definition xtd_about_box.h:10
Remarks
A xtd::diagnostics::process component provides access to a process that is running on a computer. A process, in the simplest terms, is a running app. A thread is the basic unit to which the operating system allocates processor time. A thread can execute any part of the code of the process, including parts currently being executed by another thread.
The xtd::diagnostics::process component is a useful tool for starting, stopping, controlling, and monitoring apps. You can use the xtd::diagnostics::process component, to obtain a list of the processes that are running, or you can start a new process. A Process component is used to access system processes. After a xtd::diagnostics::process component has been initialized, it can be used to obtain information about the running process. Such information includes the set of threads, the loaded modules (.dll and .exe files), and performance information such as the amount of memory the process is using.
Note
32-bit processes cannot access the modules of a 64-bit process. If you try to get information about a 64-bit process from a 32-bit process, you will get a Win32Exception exception. A 64-bit process, on the other hand, can access the modules of a 32-bit process.
Remarks
The xtd::diagnostics::process component obtains information about a group of properties all at once. After the xtd::diagnostics::process component has obtained information about one member of any group, it will cache the values for the other properties in that group and not obtain new information about the other members of the group until you call the xtd::diagnostics::process::refresh method. Therefore, a property value is not guaranteed to be any newer than the last call to the xtd::diagnostics::process::refresh method. The group breakdowns are operating-system dependent.
If you have a path variable declared in your system using quotes, you must fully qualify that path when starting any process found in that location. Otherwise, the system will not find the path. For example, if c:\mypath is not in your path, and you add it using quotation marks: path = path%;"c:\mypath", you must fully qualify any process in c:\mypath when starting it.
A system process is uniquely identified on the system by its process identifier. Like many Windows resources, a process is also identified by its handle, which might not be unique on the computer. A handle is the generic term for an identifier of a resource. The operating system persists the process handle, which is accessed through the Handle property of the Process component, even when the process has exited. Thus, you can get the process's administrative information, such as the xtd::diagnostics::process::exit_code (usually either zero for success or a nonzero error code) and the xtd::diagnostics::process::exit_time. xtd::diagnostics::process::handles are an extremely valuable resource, so leaking handles is more virulent than leaking memory.
Examples
process.cpp, and test_forms.cpp.

Classes

class  error_data_received_event
 Represents a process error data received event. More...
 
class  exit_event
 Represents a process exit event. More...
 
class  output_data_received_event
 Represents a process output data received event. More...
 

Public Events

error_data_received_event error_data_received
 Occurs when an application writes to its redirected xtd::diagnostics::process::standard_error stream.
 
exit_event exited
 Occurs when a process exits.
 
output_data_received_event output_data_received
 Occurs each time an application writes a line to its redirected xtd::diagnostics::process::standard_output stream.
 

Public Constructors

 process ()
 Initializes a new instance of the xtd::diagnostics::process class.
 

Public Properties

int32 base_priority () const
 Gets the base priority xof the associated process.
 
bool enable_raising_events () const
 Gets whether the xtd::diagnostics::process::exited event should be raised when the process terminates.
 
processenable_raising_events (bool value)
 Sets whether the xtd::diagnostics::process::exited event should be raised when the process terminates.
 
int32 exit_code () const
 Gets the value that the associated process specified when it terminated.
 
xtd::date_time exit_time () const
 Gets the time that the associated process exited.
 
intptr handle () const
 Gets the native handle of the associated process.
 
bool has_exited () const
 Gets a value indicating whether the associated process has been terminated.
 
int32 id () const
 Gets the unique identifier for the associated process.
 
string machine_name () const
 Gets the name of the computer the associated process is running on.
 
xtd::diagnostics::process_priority_class priority_class () const
 Gets the overall priority category for the associated process.
 
processpriority_class (xtd::diagnostics::process_priority_class value)
 Sets the overall priority category for the associated process.
 
string process_name () const
 Gets the name of the process.
 
std::istream & standard_error ()
 Gets a stream used to read the error output of the application.
 
std::ostream & standard_input ()
 Gets a stream used to write the input of the application.
 
std::istream & standard_output ()
 Gets a stream used to read the textual output of the application.
 
const xtd::diagnostics::process_start_infostart_info () const
 Gets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics::process.
 
xtd::diagnostics::process_start_infostart_info ()
 Gets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics::process.
 
processstart_info (const xtd::diagnostics::process_start_info &value)
 Sets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics::process.
 
xtd::date_time start_time () const
 Gets the time that the associated process was started.
 

Public Methods

void close ()
 Frees all the resources that are associated with this component.
 
void kill ()
 Immediately stops the associated process.
 
bool start ()
 Starts (or reuses) the process resource that is specified by the xtd::diagnostics::process::start_info property of this Process component and associates it with the component.
 
processwait_for_exit ()
 Instructs the xtd::diagnostics::process component to wait indefinitely for the associated process to exit.
 
processwait_for_exit (int32 milliseconds)
 Instructs the Process component to wait the specified number of milliseconds for the associated process to exit.
 

Public Static Methods

static process start (const xtd::diagnostics::process_start_info &start_info)
 Starts the process resource that is specified by the parameter containing process start information (for example, the file name of the process to start) and associates the resource with a new xtd::diagnostics::process component.
 
static process start (const string &file_name)
 Starts a process resource by specifying the name of a document or application file and associates the resource with a new Process component.
 
static process start (const string &file_name, const string &arguments)
 Starts a process resource by specifying the name of an application and a set of command-line arguments, and associates the resource with a new xtd::diagnostics::process component.
 

Protected Methods

virtual void on_exited ()
 Raises the xtd::diagnostics::process::exited event.
 

Additional Inherited Members

- Public Member Functions inherited from xtd::object
 object ()=default
 Create a new instance of the ultimate base class object.
 
virtual bool equals (const object &obj) const noexcept
 Determines whether the specified object is equal to the current object.
 
virtual size_t get_hash_code () const noexcept
 Serves as a hash function for a particular type.
 
virtual type_object get_type () const noexcept
 Gets the type of the current instance.
 
template<typename object_t >
xtd::uptr< object_t > memberwise_clone () const
 Creates a shallow copy of the current object.
 
virtual xtd::string to_string () const noexcept
 Returns a xtd::string that represents the current object.
 
- Static Public Member Functions inherited from xtd::object
template<typename object_a_t , typename object_b_t >
static bool equals (const object_a_t &object_a, const object_b_t &object_b) noexcept
 Determines whether the specified object instances are considered equal.
 
template<typename object_a_t , typename object_b_t >
static bool reference_equals (const object_a_t &object_a, const object_b_t &object_b) noexcept
 Determines whether the specified object instances are the same instance.
 

Constructor & Destructor Documentation

◆ process()

xtd::diagnostics::process::process ( )

Initializes a new instance of the xtd::diagnostics::process class.

Remarks
If you do not specify the machine_name property, the default is the local computer, (".").
You have two options for associating a new xtd::diagnostics::process component with a process on the computer. The first option is to use the constructor to create the xtd::diagnostics::process component, set the appropriate members of the xtd::diagnostics::process::start_info property and call xtd::diagnostics::process::start to associate the xtd::diagnostics::process with a new system process. The second option is to associate the xtd::diagnostics::process with a running system process by using xtd::diagnostics::process:get_process_by_id or one of the xtd::diagnostics::process::get_processes return values.
If you use a static overload of the xtd::diagnostics::process::start method to start a new system process, the method creates a new xtd::diagnostics::process component and associates it with the process.
When the xtd::diagnostics::process_start_info::use_shell_execute property is set to its default value, true, you can start applications and documents in a way that is similar to using the Run dialog box of the Windows Start menu. When xtd::diagnostics::process_start_info::use_shell_execute is false, you can start only executables.
Any executable file that you can call from the command line can be started in one of two ways: by setting the appropriate members of the xtd::diagnostics::process:start_info property and calling the xtd::diagnostics::process::start method with no parameters, or by passing the appropriate parameter to the static_start member.
You can create a xtd::diagnostics::processes component by using the constructor, one of the static xtd::diagnostics::process::start overloads, or any of the xtd::diagnostics::process::get_process_by_id, xtd::diagnostics::process::get_processes, or xtd::diagnostics::process::get_processes_by_name methods. After you have done so, you have a view into the associated process. This is not a dynamic view that updates itself automatically when the process properties have changed in memory. Instead, you must call xtd::diagnostics::process::refresh for the component to update the xtd::diagnostics::process property information in your application.

Member Function Documentation

◆ base_priority()

int32 xtd::diagnostics::process::base_priority ( ) const

Gets the base priority xof the associated process.

Returns
The base priority, which is computed from the xtd::diagnostics::process::priority_class of the associated process.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
The value returned by this property represents the most recently refreshed base priority of the process. To get the most up to date base priority, you need to call xtd::diagnostics::process::refresh() method first.
The xtd::diagnostics::process::base_priority of the process is the starting priority for threads created within the associated process. You can view information about the base priority through the System Monitor's Priority Base counter.
Based on the time elapsed or other boosts, the operating system can change the base priority when a process should be placed ahead of others.
The xtd::diagnostics::process::base_priority property lets you view the starting priority assigned to a process. However, because it is read-only, you cannot use the xtd::diagnostics::process::base_priority to set the priority of the process. To change the priority, use the xtd::diagnostics::process::priority_class property. The xtd::diagnostics::process::base_priority is viewable using the System Monitor, while the xtd::diagnostics::process::priority_class is not. Both the xtd::diagnostics::process::base_priority and the xtd::diagnostics::process::priority_class can be viewed programmatically. The following table shows the relationship between xtd::diagnostics::process::base_priority values and xtd::diagnostics::process::priority_class values.
Windows base_priority macOS base_priority linux base_priority priority_class
4 PRIO_MIN (-20) PRIO_MIN (-20)  xtd::diagnostics::process_priority_class::idle
6 PRIO_MIN + (PRIO_MAX - PRIO_MIN) / 4 (-10) PRIO_MIN + (PRIO_MAX - PRIO_MIN) / 4 (-10)  xtd::diagnostics::process_priority_class::below_normal
8 PRIO_MIN + (PRIO_MAX - PRIO_MIN)/2 (0) PRIO_MIN + (PRIO_MAX - PRIO_MIN)/2 (0)  xtd::diagnostics::process_priority_class::normal
10 PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 4 (10) PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 4 (10)  xtd::diagnostics::process_priority_class::above_normal
13 PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 8 (15) PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 8 (15)  xtd::diagnostics::process_priority_class::high
24 PRIO_MAX (20) PRIO_MAX (20)  xtd::diagnostics::process_priority_class::real_time

◆ enable_raising_events() [1/2]

bool xtd::diagnostics::process::enable_raising_events ( ) const

Gets whether the xtd::diagnostics::process::exited event should be raised when the process terminates.

Returns
true if the xtd::diagnostics::process::exited event should be raised when the associated process is terminated (through either an exit or a call to xtd::diagnostics::process::kill()); otherwise, false. The default is false. Note that the xtd::diagnostics::process::exited event is raised even if the value of xtd::diagnostics::process::enable_raising_events is false when the process exits during or before the user performs a xtd::diagnostics::process::has_exited check.
Remarks
The xtd::diagnostics::process::enable_raising_events property suggests whether the component should be notified when the operating system has shut down a process. The xtd::diagnostics::process::enable_raising_events property is used in asynchronous processing to notify your application that a process has exited. To force your application to synchronously wait for an exit event (which interrupts processing of the application until the exit event has occurred), use the xtd::diagnostics::process::wait_for_exit method.
If the component's xtd::diagnostics::process::enable_raising_events value is true, or when xtd::diagnostics::process::enable_raising_events is false and a xtd::diagnostics::process::has_exited check is invoked by the component, the component can access the administrative information for the associated process, which remains stored by the operating system. Such information includes the xtd::diagnostics::process::exit_time and the xtd::diagnostics::process::exit_code.
After the associated process exits, the xtd::diagnostics::process::handle of the component no longer points to an existing process resource. Instead, it can only be used to access the operating system's information about the process resource. The operating system is aware that there are handles to exited processes that haven't been released by xtd::diagnostics::process components, so it keeps the xtd::diagnostics::process::exit_time and xtd::diagnostics::process::handle information in memory.
There's a cost associated with watching for a process to exit. If xtd::diagnostics::process::enable_raising_events is true, the xtd::diagnostics::process::exited event is raised when the associated process terminates. Your procedures for the xtd::diagnostics::process::exited event run at that time.
Sometimes, your application starts a process but doesn't require notification of its closure. For example, your application can start Notepad to allow the user to perform text editing but make no further use of the Notepad application. You can choose to avoid notification when the process exits because it's not relevant to the continued operation of your application. Setting xtd::diagnostics::process::enable_raising_events to false can save system resources.

◆ enable_raising_events() [2/2]

process & xtd::diagnostics::process::enable_raising_events ( bool  value)

Sets whether the xtd::diagnostics::process::exited event should be raised when the process terminates.

Parameters
valuetrue if the xtd::diagnostics::process::exited event should be raised when the associated process is terminated (through either an exit or a call to xtd::diagnostics::process::kill()); otherwise, false. The default is false. Note that the xtd::diagnostics::process::exited event is raised even if the value of xtd::diagnostics::process::enable_raising_events is false when the process exits during or before the user performs a xtd::diagnostics::process::has_exited check.
Remarks
The xtd::diagnostics::process::enable_raising_events property suggests whether the component should be notified when the operating system has shut down a process. The xtd::diagnostics::process::enable_raising_events property is used in asynchronous processing to notify your application that a process has exited. To force your application to synchronously wait for an exit event (which interrupts processing of the application until the exit event has occurred), use the xtd::diagnostics::process::wait_for_exit method.
If the component's xtd::diagnostics::process::enable_raising_events value is true, or when xtd::diagnostics::process::enable_raising_events is false and a xtd::diagnostics::process::has_exited check is invoked by the component, the component can access the administrative information for the associated process, which remains stored by the operating system. Such information includes the xtd::diagnostics::process::exit_time and the xtd::diagnostics::process::exit_code.
After the associated process exits, the xtd::diagnostics::process::handle of the component no longer points to an existing process resource. Instead, it can only be used to access the operating system's information about the process resource. The operating system is aware that there are handles to exited processes that haven't been released by xtd::diagnostics::process components, so it keeps the xtd::diagnostics::process::exit_time and xtd::diagnostics::process::handle information in memory.
There's a cost associated with watching for a process to exit. If xtd::diagnostics::process::enable_raising_events is true, the xtd::diagnostics::process::exited event is raised when the associated process terminates. Your procedures for the xtd::diagnostics::process::exited event run at that time.
Sometimes, your application starts a process but doesn't require notification of its closure. For example, your application can start Notepad to allow the user to perform text editing but make no further use of the Notepad application. You can choose to avoid notification when the process exits because it's not relevant to the continued operation of your application. Setting xtd::diagnostics::process::enable_raising_events to false can save system resources.

◆ exit_code()

int32 xtd::diagnostics::process::exit_code ( ) const

Gets the value that the associated process specified when it terminated.

Returns
The code that the associated process specified when it terminated.
Exceptions
xtd::invalid_operation_exceptionThe process has not exited.
-or-
The process xtd::diagnostics::process::handle is not valid.
xtd::not_supported_exceptionYou are trying to access the xtd::diagnostics::process::exit_code property for a process that is running on a remote computer. This property is available only for processes that are running on the local computer.
Remarks
Use xtd::diagnostics::process::exit_code to get the status that the system process returned when it exited. You can use the exit code much like an integer return value from a main() procedure.
The xtd::diagnostics::process::exit_code value for a process reflects the specific convention implemented by the application developer for that process. If you use the exit code value to make decisions in your code, be sure that you know the exit code convention used by the application process.
Developers usually indicate a successful exit by an xtd::diagnostics::process::exit_code value of zero (EXIT_SUCCESS), and designate errors by nonzero values (EXIT_FAILURE) that the calling method can use to identify the cause of an abnormal process termination. It is not necessary to follow these guidelines, but they are the convention.
If you try to get the xtd::diagnostics::process::exit_code before the process has exited, the attempt throws an exception. Examine the xtd::diagnostics::process::has_exited property first to verify whether the associated process has terminated.
Note
When standard output has been redirected to asynchronous event handlers, it is possible that output processing will not have completed when HasExited returns true. To ensure that asynchronous event handling has been completed, call the xtd::diagnostics::wait_for_exit() overload that takes no parameter before checking xtd::diagnostics::has_exited.
Remarks
You can use the xtd::diagnostics::process::close_main_window or the xtd::diagnostics::process::kill method to cause an associated process to exit.
There are two ways of being notified when the associated process exits: synchronously and asynchronously. Synchronous notification relies on calling the xtd::diagnostics::process::wait_for_exit method to pause the processing of your application until the associated component exits. Asynchronous notification relies on the xtd::diagnostics::process::exited event. When using asynchronous notification, xtd::diagnostics::process::enable_raising_events must be set to true for the xtd::diagnostics::process component to receive notification that the process has exited.

◆ exit_time()

xtd::date_time xtd::diagnostics::process::exit_time ( ) const

Gets the time that the associated process exited.

Returns
A xtd::date_time that indicates when the associated process was terminated.
Exceptions
xtd::not_supported_exceptionYou are trying to access the xtd::diagnostics::process::exit_time property for a process that is running on a remote computer. This property is available only for processes that are running on the local computer.
Remarks
If the process has not terminated, attempting to retrieve the xtd::diagnostics::process::exit_time property throws an exception. Use xtd::diagnostics::process::has_exited before getting the xtd::diagnostics::process::exit_time property to determine whether the associated process has terminated.

◆ handle()

intptr xtd::diagnostics::process::handle ( ) const

Gets the native handle of the associated process.

Returns
The handle that the operating system assigned to the associated process when the process was started. The system uses this handle to keep track of process attributes.
Exceptions
xtd::invalid_operation_exceptionThe process has not been started or has exited. The xtd::diagnostics::process::handle property cannot be read because there is no process associated with this xtd::diagnostics::process instance.
-or-
The xtd::diagnostics::process instance has been attached to a running process but you do not have the necessary permissions to get a handle with full access rights.
xtd::not_supported_exceptionYou are trying to access the xtd::diagnostics::process::handle property for a process that is running on a remote computer. This property is available only for processes that are running on the local computer.
Remarks
An application can obtain a handle to a process that can be used as a parameter to many process-information and control functions. You can use this handle to initialize a xtd::diagnostics::wait_handle or to call native methods with platform invoke.
This process handle is private to an application–in other words, process handles cannot be shared. A process also has a process Id which, unlike the xtd::diagnostics::process::handle, is unique and, therefore, valid throughout the system.
Only processes started through a call to xtd::diagnostics::process::start set the xtd::diagnostics::process::handle property of the corresponding xtd::diagnostics::process instances.

◆ has_exited()

bool xtd::diagnostics::process::has_exited ( ) const

Gets a value indicating whether the associated process has been terminated.

Returns
true if the operating system process referenced by the process component has terminated; otherwise, false.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with the object.
xtd::not_supported_exceptionYou are trying to access the xtd::diagnostics::process::has_exited property for a process that is running on a remote computer. This property is available only for processes that are running on the local computer.
Remarks
A value of true for xtd::diagnostics::process::has_exited indicates that the associated process has terminated, either normally or abnormally. You can request or force the associated process to exit by calling xtd::diagnostics::process::close_main_window or xtd::diagnostics::process::kill. If a handle is open to the process, the operating system releases the process memory when the process has exited, but retains administrative information about the process, such as the handle, exit code, and exit time. To get this information, you can use the xtd::diagnostics::process::exit_code and xtd::diagnostics::process::exit_time properties. These properties are populated automatically for processes that were started by this component. The administrative information is released when all the Process components that are associated with the system process are destroyed and hold no more handles to the exited process.
A process can terminate independently of your code. If you started the process using this component, the system updates the value of xtd::diagnostics::process::has_exited automatically, even if the associated process exits independently.
Note
When standard output has been redirected to asynchronous event handlers, it is possible that output processing will not have completed when HasExited returns true. To ensure that asynchronous event handling has been completed, call the xtd::diagnostics::wait_for_exit() overload that takes no parameter before checking xtd::diagnostics::has_exited.

◆ id()

int32 xtd::diagnostics::process::id ( ) const

Gets the unique identifier for the associated process.

Returns
The system-generated unique identifier of the process that is referenced by this process instance.
Exceptions
xtd::invalid_operation_exceptionThe process's Id property has not been set.
Remarks
The process xtd::diagnostics::process::id is not valid if the associated process is not running. Therefore, you should ensure that the process is running before attempting to retrieve the xtd::diagnostics::process::id property. Until the process terminates, the process identifier uniquely identifies the process throughout the system.
You can connect a process that is running on a local or remote computer to a new xtd::diagnostics::process instance by passing the process identifier to the xtd::diagnostics::process::get_process_by_id method. xtd::diagnostics::process::get_process_by_id is a static method that creates a new component and sets the xtd::diagnostics::process::id property for the new xtd::diagnostics::process instance automatically.
Process identifiers can be reused by the system. The xtd::diagnostics::process::id property value is unique only while the associated process is running. After the process has terminated, the system can reuse the xtd::diagnostics::process::id property value for an unrelated process.
Because the identifier is unique on the system, you can pass it to other threads as an alternative to passing a xtd::diagnostics::process instance. This action can save system resources yet guarantee that the process is correctly identified.

◆ machine_name()

string xtd::diagnostics::process::machine_name ( ) const

Gets the name of the computer the associated process is running on.

Returns
The name of the computer that the associated process is running on.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
You can view statistical data and process information for processes running on remote computers but you cannot call xtd::diagnostics::process::start, xtd::diagnostics::process::close_main_window, or xtd::diagnostics::process::kill on remote computers.
Note
When the associated process is executing on the local machine, this property returns a period (".") for the machine name. You should use the xtd::environment::machine_name property to get the correct machine name.

◆ priority_class() [1/2]

xtd::diagnostics::process_priority_class xtd::diagnostics::process::priority_class ( ) const

Gets the overall priority category for the associated process.

Returns
The priority category for the associated process, from which the xtd::diagnostics::process::base_priority of the process is calculated.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
The value returned by this property represents the most recently refreshed priority of the process. To get the most up to date priority, you need to call xtd::diagnostics::process::refresh() method first.
A process priority class encompasses a range of thread priority levels. Threads with different priorities that are running in the process run relative to the priority class of the process. Win32 uses four priority classes with seven base priority levels per class. These process priority classes are captured in the xtd::diagnostics::process_priority_class enumeration, which lets you set the process priority to xtd::diagnostics::process_priority_class::idle, xtd::diagnostics::process_priority_class::normal, xtd::diagnostics::process_priority_class::high, xtd::diagnostics::process_priority_class::above_normal, xtd::diagnostics::process_priority_class::xtd::diagnostics::process_priority_class::below_normal, or xtd::diagnostics::process_priority_class::real_time. Based on the time elapsed or other boosts, the base priority level can be changed by the operating system when a process needs to be put ahead of others for access to the processor. In addition, you can set the xtd::diagnostics::process::priority_boost_enabled to temporarily boost the priority level of threads that have been taken out of the wait state. The priority is reset when the process returns to the wait state.
The xtd::diagnostics::process::base_priority property lets you view the starting priority that is assigned to a process. However, because it is read-only, you cannot use the xtd::diagnostics::process::base_priority property to set the priority of a process. To change the priority, use the xtd::diagnostics::process::priority_class property, which gets or sets the overall priority category for the process.
The priority class cannot be viewed using System Monitor. The following table shows the relationship between the xtd::diagnostics::process::base_priority and xtd::diagnostics::process::priority_class values.
Windows base_priority macOS base_priority linux base_priority priority_class
4 PRIO_MIN (-20) PRIO_MIN (-20)  xtd::diagnostics::process_priority_class::idle
6 PRIO_MIN + (PRIO_MAX - PRIO_MIN) / 4 (-10) PRIO_MIN + (PRIO_MAX - PRIO_MIN) / 4 (-10)  xtd::diagnostics::process_priority_class::below_normal
8 PRIO_MIN + (PRIO_MAX - PRIO_MIN)/2 (0) PRIO_MIN + (PRIO_MAX - PRIO_MIN)/2 (0)  xtd::diagnostics::process_priority_class::normal
10 PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 4 (10) PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 4 (10)  xtd::diagnostics::process_priority_class::above_normal
13 PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 8 (15) PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 8 (15)  xtd::diagnostics::process_priority_class::high
24 PRIO_MAX (20) PRIO_MAX (20)  xtd::diagnostics::process_priority_class::real_time

◆ priority_class() [2/2]

process & xtd::diagnostics::process::priority_class ( xtd::diagnostics::process_priority_class  value)

Sets the overall priority category for the associated process.

Parameters
valueThe priority category for the associated process, from which the xtd::diagnostics::process::base_priority of the process is calculated.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
The value returned by this property represents the most recently refreshed priority of the process. To get the most up to date priority, you need to call xtd::diagnostics::process::refresh() method first.
A process priority class encompasses a range of thread priority levels. Threads with different priorities that are running in the process run relative to the priority class of the process. Win32 uses four priority classes with seven base priority levels per class. These process priority classes are captured in the xtd::diagnostics::process_priority_class enumeration, which lets you set the process priority to xtd::diagnostics::process_priority_class::idle, xtd::diagnostics::process_priority_class::normal, xtd::diagnostics::process_priority_class::high, xtd::diagnostics::process_priority_class::above_normal, xtd::diagnostics::process_priority_class::xtd::diagnostics::process_priority_class::below_normal, or xtd::diagnostics::process_priority_class::real_time. Based on the time elapsed or other boosts, the base priority level can be changed by the operating system when a process needs to be put ahead of others for access to the processor. In addition, you can set the xtd::diagnostics::process::priority_boost_enabled to temporarily boost the priority level of threads that have been taken out of the wait state. The priority is reset when the process returns to the wait state.
The xtd::diagnostics::process::base_priority property lets you view the starting priority that is assigned to a process. However, because it is read-only, you cannot use the xtd::diagnostics::process::base_priority property to set the priority of a process. To change the priority, use the xtd::diagnostics::process::priority_class property, which gets or sets the overall priority category for the process.
The priority class cannot be viewed using System Monitor. The following table shows the relationship between the xtd::diagnostics::process::base_priority and xtd::diagnostics::process::priority_class values.
Windows base_priority macOS base_priority linux base_priority priority_class
4 PRIO_MIN (-20) PRIO_MIN (-20)  xtd::diagnostics::process_priority_class::idle
6 PRIO_MIN + (PRIO_MAX - PRIO_MIN) / 4 (-10) PRIO_MIN + (PRIO_MAX - PRIO_MIN) / 4 (-10)  xtd::diagnostics::process_priority_class::below_normal
8 PRIO_MIN + (PRIO_MAX - PRIO_MIN)/2 (0) PRIO_MIN + (PRIO_MAX - PRIO_MIN)/2 (0)  xtd::diagnostics::process_priority_class::normal
10 PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 4 (10) PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 4 (10)  xtd::diagnostics::process_priority_class::above_normal
13 PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 8 (15) PRIO_MAX - (PRIO_MAX - PRIO_MIN) / 8 (15)  xtd::diagnostics::process_priority_class::high
24 PRIO_MAX (20) PRIO_MAX (20)  xtd::diagnostics::process_priority_class::real_time

◆ process_name()

string xtd::diagnostics::process::process_name ( ) const

Gets the name of the process.

Returns
The name that the system uses to identify the process to the user.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
The xtd::diagnostics::process::process_name property holds an executable file name, such as Outlook, that does not include the .exe extension or the path. It is helpful for getting and manipulating all the processes that are associated with the same executable file.
You can call xtd::diagnostics::process::get_processes_by_name, passing it an executable file name, to retrieve an array that contains every running instance on the specified computer. You can use this array, for example, to shut down all the running instances of the executable file.

◆ standard_error()

std::istream & xtd::diagnostics::process::standard_error ( )

Gets a stream used to read the error output of the application.

Returns
A std::istream that can be used to read the standard error stream of the application.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Examples
The following example uses the net use command together with a user supplied argument to map a network resource. It then reads the standard error stream of the net command and writes it to console.
xtd::diagnostics::process_start_info my_process_start_info("net ", "use " + args[0]);
my_process_start_info.use_shell_execute(false);
my_process_start_info.redirect_standard_error(true);
my_process.start_info(my_process_start_info);
my_process.start();
xtd::io::stream_reader my_stream_reader(my_process.standard_error());
// Read the standard error of net.exe and write it on to console.
xtd::console::write_line(my_stream_reader.read_line());
}
Specifies a set of values that are used when you start a process.
Definition process_start_info.h:39
const xtd::diagnostics::process_start_info & start_info() const
Gets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics:...
std::istream & standard_error()
Gets a stream used to read the error output of the application.
bool start()
Starts (or reuses) the process resource that is specified by the xtd::diagnostics::process::start_inf...
Implements a xtd::io::text_reader that reads characters from a byte stream.
Definition stream_reader.h:28
Remarks
When a xtd::diagnostics::process writes text to its standard error stream, that text is normally displayed on the console. By redirecting the xtd::diagnostics::process::standard_error stream, you can manipulate or suppress the error output of a process. For example, you can filter the text, format it differently, or write the output to both the console and a designated log file.
Note
To use xtd::diagnostics::process::standard_error, you must set xtd::diagnostics::process_start_info::use_shell_execute to false, and you must set xtd::diagnostics::process_start_info::redirect_standard_error to true. Otherwise, reading from the xtd::diagnostics::process::standard_error stream throws an exception.
Remarks
The redirected xtd::diagnostics::process::standard_error stream can be read synchronously or asynchronously. Methods such as xtd::io::stream_reader::read, xtd::io::stream_reader::read_line, and xtd::io::stream_reader::read_to_end perform synchronous read operations on the error output stream of the process. These synchronous read operations do not complete until the associated xtd::diagnostics::process writes to its xtd::diagnostics::process::standard_error stream, or closes the stream.
In contrast, xtd::diagnostics::process::begin_error_read_line starts asynchronous read operations on the xtd::diagnostics::process::standard_error stream. This method enables a designated event handler for the stream output and immediately returns to the caller, which can perform other work while the stream output is directed to the event handler.
Synchronous read operations introduce a dependency between the caller reading from the xtd::diagnostics::process::standard_error stream and the child process writing to that stream. These dependencies can result in deadlock conditions. When the caller reads from the redirected stream of a child process, it is dependent on the child. The caller waits on the read operation until the child writes to the stream or closes the stream. When the child process writes enough data to fill its redirected stream, it is dependent on the parent. The child process waits on the next write operation until the parent reads from the full stream or closes the stream. The deadlock condition results when the caller and child process wait on each other to complete an operation, and neither can proceed. You can avoid deadlocks by evaluating dependencies between the caller and child process.
The last two examples in this section use the xtd::diagnostics:process::start method to launch an executable named Write500Lines.exe. The following example contains its source code.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::io;
auto main() -> int {
for (int ctr = 0; ctr < 500; ctr++)
console::write_line("Line {} of 500 written: {:P2}", ctr + 1, (ctr + 1)/500.0);
console::error << "\nSuccessfully wrote 500 lines.\n";
}
// The example displays the following output:
// The last 40 characters in the output stream are:
// ': 99.80%
// Line 500 of 500 written: 100.00%
// '
//
// Successfully wrote 500 lines.
static std::ostream error
Gets the error output stream. A std::basic_ostream<char_t> that represents the error output stream.
Definition console.h:42
The xtd::io namespace contains types that allow reading and writing to files and data streams,...
Definition binary_reader.h:16
The following example shows how to read from a redirected error stream and wait for the child process to exit. It avoids a deadlock condition by calling stream_reader(p.standard_error()).read_to_end() before p.wait_for_exit. A deadlock condition can result if the parent process calls p.wait_for_exit before stream_reader(p.standard_error()).read_to_end() and the child process writes enough text to fill the redirected stream. The parent process would wait indefinitely for the child process to exit. The child process would wait indefinitely for the parent to read from the full xtd::diagnostics::process::standard_error stream.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
auto main() -> int {
auto p = process();
p.start_info().use_shell_execute(false);
p.start_info().redirect_standard_error(true);
p.start_info().file_name("write_500_lines");
p.start();
// To avoid deadlocks, always read the output stream first and then wait.
string output = stream_reader(p.standard_error()).read_to_end();
p.wait_for_exit();
console::write_line("\nError stream: {}", output);
}
// The end of the output produced by the example includes the following:
// Error stream: Successfully wrote 500 lines.
process()
Initializes a new instance of the xtd::diagnostics::process class.
virtual xtd::string read_to_end()
Reads all characters from the current position to the end of the text_reader and returns them as one ...
@ p
The P key.
There is a similar issue when you read all text from both the standard output and standard error streams. The following example performs a read operation on both streams. It avoids the deadlock condition by performing asynchronous read operations on the xtd::diagnostics::process::standard_error stream. A deadlock condition results if the parent process calls stream_reader(p.standard_output()).read_to_end() followed by stream_reader(p.standard_error()).read_to_end() and the child process writes enough text to fill its error stream. The parent process would wait indefinitely for the child process to close its xtd::diagnostics::process::standard_output stream. The child process would wait indefinitely for the parent to read from the full xtd::diagnostics::process::standard_error stream.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
auto main() -> int {
auto p = process();
p.start_info().use_shell_execute(false);
p.start_info().redirect_standard_output(true);
string e_out;
p.start_info().redirect_standard_error(true);
p.error_data_received += [&](object& sender, const data_received_event_args& e) {
e_out += e.data();
};
p.start_info().file_name("write_500_lines");
p.start();
// To avoid deadlocks, always read the output stream first and then wait.
p.begin_error_read_line();
string output = stream_reader(p.standard_error()).read_to_end();
p.wait_for_exit();
console::write_line("\nError stream: {}", output);
}
// The example displays the following output:
// The last 40 characters in the output stream are:
// ': 99.80%
// Line 500 of 500 written: 100.00%
// '
//
// Error stream: Successfully wrote 500 lines.
Provides data for the xtd::diagnostics::process::output_data_received and xtd::diagnostics::process::...
Definition data_received_event_args.h:28
You can use asynchronous read operations to avoid these dependencies and their deadlock potential. Alternately, you can avoid the deadlock condition by creating two threads and reading the output of each stream on a separate thread.
Note
You cannot mix asynchronous and synchronous read operations on a redirected stream. Once the redirected stream of a xtd::diagnostics::process is opened in either asynchronous or synchronous mode, all further read operations on that stream must be in the same mode. For example, do not follow xtd::diagnostics::process::begin_error_read_line with a call to xtd::io::stream_reader::read_line on the xtd::diagnostics::process::standard_error stream, or vice versa. However, you can read two different streams in different modes. For example, you can call xtd::diagnostics::process::begin_output_read_line and then call xtd::io::sstream_reader::read_line for the xtd::diagnostics::process::standard_error stream.

◆ standard_input()

std::ostream & xtd::diagnostics::process::standard_input ( )

Gets a stream used to write the input of the application.

Returns
A std::ostream that can be used to write the standard input stream of the application.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::processes object.
Examples
The following example illustrates how to redirect the xtd::diagnostics::process::standard_input stream of a process. The example starts the sort command with redirected input. It then prompts the user for text, and passes that to the sort process by means of the redirected xtd::diagnostics::process::standard_input stream. The sort results are displayed to the user on the console.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
auto main() -> int {
console::write_line("Ready to sort one or more text lines...");
// Start the sort process with redirected input.
// Use the sort command to sort the input text.
block_scope_(process my_process) {
my_process.start_info().file_name("sort");
my_process.start_info().use_shell_execute(false);
my_process.start_info().redirect_standard_input(true);
my_process.start();
stream_writer my_stream_writer(my_process.standard_input());
// Prompt the user for input text lines to sort.
// Write each line to the StandardInput stream of
// the sort command.
string input_text;
int num_lines = 0;
do {
console::write_line("Enter a line of text (or press the Enter key to stop):");
input_text = console::read_line();
if (input_text.size() > 0) {
num_lines++;
my_stream_writer.write_line(input_text);
}
} while (input_text.size() > 0);
// Write a report header to the console.
if (num_lines > 0) {
console::write_line(" {} sorted text line(s) ", num_lines);
console::write_line("------------------------");
} else {
console::write_line(" No input was sorted");
}
// End the input stream to the sort command.
// When the stream closes, the sort command
// writes the sorted text lines to the
// console.
my_stream_writer.close();
// Wait for the sort process to write the sorted text lines.
my_process.wait_for_exit();
}
}
size_type size() const noexcept
Returns the number of char_t elements in the string, i.e. std::distance(begin(), end()).
Definition basic_string.h:934
static xtd::string read_line()
Reads the next line of characters from the standard input stream.
bool redirect_standard_input() const noexcept
Gets a value indicating whether the input for an application is read from the Process....
const xtd::string & file_name() const noexcept
Gets the application or document to start.
bool use_shell_execute() const noexcept
Gets a value indicating whether to use the operating system shell to start the process.
std::ostream & standard_input()
Gets a stream used to write the input of the application.
process & wait_for_exit()
Instructs the xtd::diagnostics::process component to wait indefinitely for the associated process to ...
Implements a xtd::io::text_writer for writing characters to a stream.
Definition stream_writer.h:28
Remarks
A xtd::diagnostics::process can read input text from its standard input stream, typically the keyboard. By redirecting the xtd::diagnostics::process::standard_input stream, you can programmatically specify the input. For example, instead of using keyboard input, you can provide text from the contents of a designated file or output from another application.
Note
To use xtd::diagnostics::process::standard_input, you must set xtd::diagnostics::process_start_info::use_shell_execute to false, and you must set xtd::diagnostics::process_start_info::redirect_standard_input to true. Otherwise, writing to the xtd::diagnostics::process::standard_input stream throws an exception.

◆ standard_output()

std::istream & xtd::diagnostics::process::standard_output ( )

Gets a stream used to read the textual output of the application.

Returns
A std::istream that can be used to read the standard output stream of the application.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Examples
The following example runs the ipconfig.exe command and redirects its standard output to the example's console window.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
auto main() -> int {
process.start_info().file_name("ipconfig");
// Synchronously read the standard output of the spawned process.
string output = reader.read_to_end();
// Write the redirected output to this application's window.
}
console::write_line("\n\nPress any key to exit.");
}
bool redirect_standard_output() const noexcept
Gets a value that indicates whether the textual output of an application is written to the xtd::diagn...
std::istream & standard_output()
Gets a stream used to read the textual output of the application.
Remarks
When a xtd::diagnostics::process writes text to its standard stream, that text is normally displayed on the console. By redirecting the xtd::diagnostics::process::standard_output stream, you can manipulate or suppress the output of a process. For example, you can filter the text, format it differently, or write the output to both the console and a designated log file.
Note
To use xtd::diagnostics::process::standard_output, you must set xtd::diagnostics::process_start_info::use_shell_execute to false, and you must set xtd::diagnostics::process_start_info::redirect_standard_output to true. Otherwise, reading from the xtd::diagnostics::process::standard_output stream throws an exception.
Remarks
The redirected xtd::diagnostics::process::standard_output stream can be read synchronously or asynchronously. Methods such as xtd::io::stream_reader::read, xtd::io::stream_reader::read_line, and xtd::io::stream_reader::read_to_end perform synchronous read operations on the output stream of the process. These synchronous read operations do not complete until the associated Process writes to its xtd::diagnostics::process::xtd::diagnostics::process::standard_output stream, or closes the stream.
In contrast, xtd::diagnostics::process::begin_output_read_line starts asynchronous read operations on the xtd::diagnostics::process::standard_output stream. This method enables a designated event handler for the stream output and immediately returns to the caller, which can perform other work while the stream output is directed to the event handler.
Synchronous read operations introduce a dependency between the caller reading from the xtd::diagnostics::process::standard_output stream and the child process writing to that stream. These dependencies can result in deadlock conditions. When the caller reads from the redirected stream of a child process, it is dependent on the child. The caller waits on the read operation until the child writes to the stream or closes the stream. When the child process writes enough data to fill its redirected stream, it is dependent on the parent. The child process waits on the next write operation until the parent reads from the full stream or closes the stream. The deadlock condition results when the caller and child process wait on each other to complete an operation, and neither can proceed. You can avoid deadlocks by evaluating dependencies between the caller and child process.
The last two examples in this section use the xtd::diagnostics:process::start method to launch an executable named Write500Lines.exe. The following example contains its source code.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::io;
auto main() -> int {
for (int ctr = 0; ctr < 500; ctr++)
console::write_line("Line {} of 500 written: {:P2}", ctr + 1, (ctr + 1)/500.0);
console::error << "\nSuccessfully wrote 500 lines.\n";
}
// The example displays the following output:
// The last 40 characters in the output stream are:
// ': 99.80%
// Line 500 of 500 written: 100.00%
// '
//
// Successfully wrote 500 lines.
The following example shows how to read from a redirected error stream and wait for the child process to exit. It avoids a deadlock condition by calling stream_reader(p.standard_error()).read_to_end() before p.wait_for_exit. A deadlock condition can result if the parent process calls p.wait_for_exit before stream_reader(p.standard_error()).read_to_end() and the child process writes enough text to fill the redirected stream. The parent process would wait indefinitely for the child process to exit. The child process would wait indefinitely for the parent to read from the full xtd::diagnostics::process::standard_error stream.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
auto main() -> int {
auto p = process();
p.start_info().use_shell_execute(false);
p.start_info().redirect_standard_error(true);
p.start_info().file_name("write_500_lines");
p.start();
// To avoid deadlocks, always read the output stream first and then wait.
string output = stream_reader(p.standard_error()).read_to_end();
p.wait_for_exit();
console::write_line("\nError stream: {}", output);
}
// The end of the output produced by the example includes the following:
// Error stream: Successfully wrote 500 lines.
There is a similar issue when you read all text from both the standard output and standard error streams. The following example performs a read operation on both streams. It avoids the deadlock condition by performing asynchronous read operations on the xtd::diagnostics::process::standard_error stream. A deadlock condition results if the parent process calls stream_reader(p.standard_output()).read_to_end() followed by stream_reader(p.standard_error()).read_to_end() and the child process writes enough text to fill its error stream. The parent process would wait indefinitely for the child process to close its xtd::diagnostics::process::standard_output stream. The child process would wait indefinitely for the parent to read from the full xtd::diagnostics::process::standard_error stream.
#include <xtd/xtd>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
auto main() -> int {
auto p = process();
p.start_info().use_shell_execute(false);
p.start_info().redirect_standard_output(true);
string e_out;
p.start_info().redirect_standard_error(true);
p.error_data_received += [&](object& sender, const data_received_event_args& e) {
e_out += e.data();
};
p.start_info().file_name("write_500_lines");
p.start();
// To avoid deadlocks, always read the output stream first and then wait.
p.begin_error_read_line();
string output = stream_reader(p.standard_error()).read_to_end();
p.wait_for_exit();
console::write_line("\nError stream: {}", output);
}
// The example displays the following output:
// The last 40 characters in the output stream are:
// ': 99.80%
// Line 500 of 500 written: 100.00%
// '
//
// Error stream: Successfully wrote 500 lines.
You can use asynchronous read operations to avoid these dependencies and their deadlock potential. Alternately, you can avoid the deadlock condition by creating two threads and reading the output of each stream on a separate thread.
Note
You cannot mix asynchronous and synchronous read operations on a redirected stream. Once the redirected stream of a xtd::diagnostics::process is opened in either asynchronous or synchronous mode, all further read operations on that stream must be in the same mode. For example, do not follow xtd::diagnostics::process::begin_output_read_line with a call to xtd::io::stream_reader::read_line on the xtd::diagnostics::process::standard_output stream, or vice versa. However, you can read two different streams in different modes. For example, you can call xtd::diagnostics::process::begin_output_read_line and then call xtd::io::stream_reader::read_line for the xtd::diagnostics::process::standard_error stream.

◆ start_info() [1/3]

const xtd::diagnostics::process_start_info & xtd::diagnostics::process::start_info ( ) const

Gets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics::process.

Returns
The xtd::diagnostics::process_start_info that represents the data with which to start the process. These arguments include the name of the executable file or document used to start the process.
Examples
The following example populates a StartInfo with the file to execute, the action performed on it and whether it should displays a user interface. For additional examples, refer to the reference pages for properties of the ProcessStartInfo class.
#include <xtd/diagnostics/process>
#include <xtd/block_scope>
#include <xtd/console>
using namespace xtd;
using namespace xtd::diagnostics;
auto main() -> int {
try {
block_scope_(auto my_process = process {}) {
my_process.start_info().use_shell_execute(false);
// You can start any process other guidgen.
my_process.start_info().file_name("guidgen");
my_process.start_info().create_no_window(true);
my_process.start();
// This code assumes the process you are starting will terminate itself.
// Given that it is started without a window so you cannot terminate it
// on the desktop, it must terminate itself or you can do it programmatically
// from this application using the kill method.
}
} catch (const std::exception& e) {
}
}
// This code can produce the following output :
//
// 1549cf47-b1c9-4333-96e5-4eabffbd9fbd
Remarks
xtd::diagnostics::process_start_info represents the set of parameters to use to start a process. When xtd::diagnostics::process::start is called, the xtd::diagnostics::process::start_info is used to specify the process to start. The only necessary xtd::diagnostics::process::start_info member to set is the xtd::diagnostics::process_start_info::file_name property. Starting a process by specifying the xtd::diagnostics::process_start_info::file_name property is similar to typing the information in the Run dialog box of the Windows Start menu. Therefore, the xtd::diagnostics::process_start_info::file_name property does not need to represent an executable file. It can be of any file type for which the extension has been associated with an application installed on the system. For example the xtd::diagnostics::process_start_info::file_name can have a .txt extension if you have associated text files with an editor, such as Notepad, or it can have a .doc if you have associated .doc files with a word processing tool, such as Microsoft Word. Similarly, in the same way that the Run dialog box can accept an executable file name with or without the .exe extension, the .exe extension is optional in the xtd::diagnostics::process_start_info::file_name member. For example, you can set the xtd::diagnostics::process_start_info::file_name property to either "Notepad.exe" or "Notepad".
If the file name involves a nonexecutable file, such as a .doc file, you can include a verb specifying what action to take on the file. For example, you could set the Verb to "Print" for a file ending in the .doc extension. The file name specified in the xtd::diagnostics::process::start_info::file_name property does not need to have an extension if you manually enter a value for the Verb property. However, if you use the Verbs property to determine what verbs are available, you must include the extension.
You can change the parameters specified in the xtd::diagnostics::process::start_info property up to the time that you call the xtd::diagnostics::process::start method on the process. After you start the process, changing the xtd::diagnostics::process::start_info values does not affect or restart the associated process. If you call the xtd::diagnostics::process::start(xtd::diagnostics::process_start_info) method with the xtd::diagnostics::process_start_info. xtd::diagnostics::process::start_info::user_name and xtd::diagnostics::process::start_info::password properties set, the unmanaged CreateProcessWithLogonW function is called, which starts the process in a new window even if the xtd::diagnostics::process::start_info::create_no_window property value is true or the xtd::diagnostics::process::start_info::window_style property value is xtd::diagnostics::process_window_style::hidden.
You should only access the xtd::diagnostics::process::start_info property on a xtd::diagnostics::process object returned by the Start method. For example, you should not access the xtd::diagnostics::process::start_info property on a xtd::diagnostics::process object returned by xtd::diagnostics::process::get_processes.

◆ start_info() [2/3]

xtd::diagnostics::process_start_info & xtd::diagnostics::process::start_info ( )

Gets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics::process.

Returns
The xtd::diagnostics::process_start_info that represents the data with which to start the process. These arguments include the name of the executable file or document used to start the process.
Examples
The following example populates a StartInfo with the file to execute, the action performed on it and whether it should displays a user interface. For additional examples, refer to the reference pages for properties of the ProcessStartInfo class.
#include <xtd/diagnostics/process>
#include <xtd/block_scope>
#include <xtd/console>
using namespace xtd;
using namespace xtd::diagnostics;
auto main() -> int {
try {
block_scope_(auto my_process = process {}) {
my_process.start_info().use_shell_execute(false);
// You can start any process other guidgen.
my_process.start_info().file_name("guidgen");
my_process.start_info().create_no_window(true);
my_process.start();
// This code assumes the process you are starting will terminate itself.
// Given that it is started without a window so you cannot terminate it
// on the desktop, it must terminate itself or you can do it programmatically
// from this application using the kill method.
}
} catch (const std::exception& e) {
}
}
// This code can produce the following output :
//
// 1549cf47-b1c9-4333-96e5-4eabffbd9fbd
Remarks
xtd::diagnostics::process_start_info represents the set of parameters to use to start a process. When xtd::diagnostics::process::start is called, the xtd::diagnostics::process::start_info is used to specify the process to start. The only necessary xtd::diagnostics::process::start_info member to set is the xtd::diagnostics::process_start_info::file_name property. Starting a process by specifying the xtd::diagnostics::process_start_info::file_name property is similar to typing the information in the Run dialog box of the Windows Start menu. Therefore, the xtd::diagnostics::process_start_info::file_name property does not need to represent an executable file. It can be of any file type for which the extension has been associated with an application installed on the system. For example the xtd::diagnostics::process_start_info::file_name can have a .txt extension if you have associated text files with an editor, such as Notepad, or it can have a .doc if you have associated .doc files with a word processing tool, such as Microsoft Word. Similarly, in the same way that the Run dialog box can accept an executable file name with or without the .exe extension, the .exe extension is optional in the xtd::diagnostics::process_start_info::file_name member. For example, you can set the xtd::diagnostics::process_start_info::file_name property to either "Notepad.exe" or "Notepad".
If the file name involves a nonexecutable file, such as a .doc file, you can include a verb specifying what action to take on the file. For example, you could set the Verb to "Print" for a file ending in the .doc extension. The file name specified in the xtd::diagnostics::process::start_info::file_name property does not need to have an extension if you manually enter a value for the Verb property. However, if you use the Verbs property to determine what verbs are available, you must include the extension.
You can change the parameters specified in the xtd::diagnostics::process::start_info property up to the time that you call the xtd::diagnostics::process::start method on the process. After you start the process, changing the xtd::diagnostics::process::start_info values does not affect or restart the associated process. If you call the xtd::diagnostics::process::start(xtd::diagnostics::process_start_info) method with the xtd::diagnostics::process_start_info. xtd::diagnostics::process::start_info::user_name and xtd::diagnostics::process::start_info::password properties set, the unmanaged CreateProcessWithLogonW function is called, which starts the process in a new window even if the xtd::diagnostics::process::start_info::create_no_window property value is true or the xtd::diagnostics::process::start_info::window_style property value is xtd::diagnostics::process_window_style::hidden.
You should only access the xtd::diagnostics::process::start_info property on a xtd::diagnostics::process object returned by the Start method. For example, you should not access the xtd::diagnostics::process::start_info property on a xtd::diagnostics::process object returned by xtd::diagnostics::process::get_processes.

◆ start_info() [3/3]

process & xtd::diagnostics::process::start_info ( const xtd::diagnostics::process_start_info value)

Sets the properties to pass to the xtd::diagnostics::process::start() method of the xtd::diagnostics::process.

Parameters
valueThe xtd::diagnostics::process_start_info that represents the data with which to start the process. These arguments include the name of the executable file or document used to start the process.
Examples
The following example populates a StartInfo with the file to execute, the action performed on it and whether it should displays a user interface. For additional examples, refer to the reference pages for properties of the ProcessStartInfo class.
#include <xtd/diagnostics/process>
#include <xtd/block_scope>
#include <xtd/console>
using namespace xtd;
using namespace xtd::diagnostics;
auto main() -> int {
try {
block_scope_(auto my_process = process {}) {
my_process.start_info().use_shell_execute(false);
// You can start any process other guidgen.
my_process.start_info().file_name("guidgen");
my_process.start_info().create_no_window(true);
my_process.start();
// This code assumes the process you are starting will terminate itself.
// Given that it is started without a window so you cannot terminate it
// on the desktop, it must terminate itself or you can do it programmatically
// from this application using the kill method.
}
} catch (const std::exception& e) {
}
}
// This code can produce the following output :
//
// 1549cf47-b1c9-4333-96e5-4eabffbd9fbd
Remarks
xtd::diagnostics::process_start_info represents the set of parameters to use to start a process. When xtd::diagnostics::process::start is called, the xtd::diagnostics::process::start_info is used to specify the process to start. The only necessary xtd::diagnostics::process::start_info member to set is the xtd::diagnostics::process_start_info::file_name property. Starting a process by specifying the xtd::diagnostics::process_start_info::file_name property is similar to typing the information in the Run dialog box of the Windows Start menu. Therefore, the xtd::diagnostics::process_start_info::file_name property does not need to represent an executable file. It can be of any file type for which the extension has been associated with an application installed on the system. For example the xtd::diagnostics::process_start_info::file_name can have a .txt extension if you have associated text files with an editor, such as Notepad, or it can have a .doc if you have associated .doc files with a word processing tool, such as Microsoft Word. Similarly, in the same way that the Run dialog box can accept an executable file name with or without the .exe extension, the .exe extension is optional in the xtd::diagnostics::process_start_info::file_name member. For example, you can set the xtd::diagnostics::process_start_info::file_name property to either "Notepad.exe" or "Notepad".
If the file name involves a nonexecutable file, such as a .doc file, you can include a verb specifying what action to take on the file. For example, you could set the Verb to "Print" for a file ending in the .doc extension. The file name specified in the xtd::diagnostics::process::start_info::file_name property does not need to have an extension if you manually enter a value for the Verb property. However, if you use the Verbs property to determine what verbs are available, you must include the extension.
You can change the parameters specified in the xtd::diagnostics::process::start_info property up to the time that you call the xtd::diagnostics::process::start method on the process. After you start the process, changing the xtd::diagnostics::process::start_info values does not affect or restart the associated process. If you call the xtd::diagnostics::process::start(xtd::diagnostics::process_start_info) method with the xtd::diagnostics::process_start_info. xtd::diagnostics::process::start_info::user_name and xtd::diagnostics::process::start_info::password properties set, the unmanaged CreateProcessWithLogonW function is called, which starts the process in a new window even if the xtd::diagnostics::process::start_info::create_no_window property value is true or the xtd::diagnostics::process::start_info::window_style property value is xtd::diagnostics::process_window_style::hidden.
You should only access the xtd::diagnostics::process::start_info property on a xtd::diagnostics::process object returned by the Start method. For example, you should not access the xtd::diagnostics::process::start_info property on a xtd::diagnostics::process object returned by xtd::diagnostics::process::get_processes.

◆ start_time()

xtd::date_time xtd::diagnostics::process::start_time ( ) const

Gets the time that the associated process was started.

Returns
An object that indicates when the process started. An exception is thrown if the process is not running.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.

◆ close()

void xtd::diagnostics::process::close ( )

Frees all the resources that are associated with this component.

Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
The xtd::diagnostics::process::close method causes the process to stop waiting for exit if it was waiting, closes the process handle, and clears process-specific properties. Close does not close the standard output, input, and error readers and writers in case they are being referenced externally.

◆ kill()

void xtd::diagnostics::process::kill ( )

Immediately stops the associated process.

Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
The xtd::diagnostics::process::kill method forces a termination of the process, while xtd::diagnostics::process::close_main_window only requests a termination. When a process with a graphical interface is executing, its message loop is in a wait state. The message loop executes every time a Windows message is sent to the process by the operating system. Calling xtd::diagnostics::process::close_main_window sends a request to close the main window, which, in a well-formed application, closes child windows and revokes all running message loops for the application. The request to exit the process by calling xtd::diagnostics::process::close_main_window does not force the application to quit. The application can ask for user verification before quitting, or it can refuse to quit. To force the application to quit, use the xtd::diagnostics::process::kill method.
The behavior of xtd::diagnostics::process::xtd::diagnostics::process::close_main_window is identical to that of a user closing an application's main window using the system menu. Therefore, the request to exit the process by closing the main window does not force the application to quit immediately.
Note
The xtd::diagnostics::process::kill method executes asynchronously. After calling the xtd::diagnostics::process::kill method, call the xtd::diagnostics::process::xtd::diagnostics::process::wait_for_exit method to wait for the process to exit, or check the xtd::diagnostics::process::has_exited property to determine if the process has exited.
The xtd::diagnostics::process::wait_for_exit method and the xtd::diagnostics::process::has_exited property do not reflect the status of descendant processes. When xtd::diagnostics::process::kill(entireProcessTree: true) is used, xtd::diagnostics::process::wait_for_exit and xtd::diagnostics::process::has_exited will indicate that exiting has completed after the given process exits, even if all descendants have not yet exited.
Remarks
Data edited by the process or resources allocated to the process can be lost if you call xtd::diagnostics::process::kill. xtd::diagnostics::process::kill causes an abnormal process termination and should be used only when necessary. xtd::diagnostics::process::close_main_window enables an orderly termination of the process and closes all windows, so it is preferable for applications with an interface. If xtd::diagnostics::process::close_main_window fails, you can use xtd::diagnostics::process::kill to terminate the process. xtd::diagnostics::process::kill is the only way to terminate processes that do not have graphical interfaces.
You can call xtd::diagnostics::process::kill and xtd::diagnostics::process::close_main_window only for processes that are running on the local computer. You cannot cause processes on remote computers to exit. You can only view information for processes running on remote computers.

◆ start() [1/4]

bool xtd::diagnostics::process::start ( )

Starts (or reuses) the process resource that is specified by the xtd::diagnostics::process::start_info property of this Process component and associates it with the component.

Returns
true if a process resource is started; false if no new process resource is started (for example, if an existing process is reused).
Exceptions
xtd::invalid_operation_exceptionNo file name was specified in the xtd::diagnostics::process component's xtd::diagnostics::process::start_info.
Examples
The following example populates a StartInfo with the file to execute, the action performed on it and whether it should displays a user interface. For additional examples, refer to the reference pages for properties of the ProcessStartInfo class.
#include <xtd/diagnostics/process>
#include <xtd/block_scope>
#include <xtd/console>
using namespace xtd;
using namespace xtd::diagnostics;
auto main() -> int {
try {
block_scope_(auto my_process = process {}) {
my_process.start_info().use_shell_execute(false);
// You can start any process other guidgen.
my_process.start_info().file_name("guidgen");
my_process.start_info().create_no_window(true);
my_process.start();
// This code assumes the process you are starting will terminate itself.
// Given that it is started without a window so you cannot terminate it
// on the desktop, it must terminate itself or you can do it programmatically
// from this application using the kill method.
}
} catch (const std::exception& e) {
}
}
// This code can produce the following output :
//
// 1549cf47-b1c9-4333-96e5-4eabffbd9fbd

◆ wait_for_exit() [1/2]

process & xtd::diagnostics::process::wait_for_exit ( )

Instructs the xtd::diagnostics::process component to wait indefinitely for the associated process to exit.

Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
xtd::diagnostics::process::wait_for_exit() makes the current thread wait until the associated process terminates. It should be called after all other methods are called on the process. To avoid blocking the current thread, use the xtd::diagnostics::process::exited event.
This method instructs the xtd::diagnostics::process component to wait an infinite amount of time for the process and event handlers to exit. This can cause an application to stop responding. For example, if you call xtd::diagnostics::process::close_main_window for a process that has a user interface, the request to the operating system to terminate the associated process might not be handled if the process is written to never enter its message loop.
This overload ensures that all processing has been completed, including the handling of asynchronous events for redirected standard output. You should use this overload after a call to the xtd::diagnostics::process::wait_for_exit(int32) overload when standard output has been redirected to asynchronous event handlers.
When an associated process exits (that is, when it is shut down by the operation system through a normal or abnormal termination), the system stores administrative information about the process and returns to the component that had called xtd::diagnostics::process::wait_for_exit(). The xtd::diagnostics::process component can then access the information, which includes the xtd::diagnostics::process::exit_time, by using the xtd::diagnostics::process::handle to the exited process.
Because the associated process has exited, the Handle property of the component no longer points to an existing process resource. Instead, the handle can be used only to access the operating system's information about the process resource. The system is aware of handles to exited processes that have not been released by xtd::diagnostics::process components, so it keeps the xtd::diagnostics::process::exit_time and xtd::diagnostics::process::handle information in memory until the xtd::diagnostics::process component specifically frees the resources. For this reason, any time you call xtd::diagnostics::process::start for a xtd::diagnostics::process instance, call xtd::diagnostics::process::close when the associated process has terminated and you no longer need any administrative information about it. xtd::diagnostics::process::close frees the memory allocated to the exited process.

◆ wait_for_exit() [2/2]

process & xtd::diagnostics::process::wait_for_exit ( int32  milliseconds)

Instructs the Process component to wait the specified number of milliseconds for the associated process to exit.

Parameters
millisecondsThe amount of time, in milliseconds, to wait for the associated process to exit. A value of 0 specifies an immediate return, and a value of -1 specifies an infinite wait.The amount of time, in milliseconds, to wait for the associated process to exit. A value of 0 specifies an immediate return, and a value of -1 specifies an infinite wait.
Exceptions
xtd::invalid_operation_exceptionThere is no process associated with this xtd::diagnostics::process object.
Remarks
xtd::diagnostics::process::wait_for_exit() makes the current thread wait until the associated process terminates. It should be called after all other methods are called on the process. To avoid blocking the current thread, use the xtd::diagnostics::process::exited event.
This method instructs the xtd::diagnostics::process component to wait an infinite amount of time for the process and event handlers to exit. This can cause an application to stop responding. For example, if you call xtd::diagnostics::process::close_main_window for a process that has a user interface, the request to the operating system to terminate the associated process might not be handled if the process is written to never enter its message loop.
This overload ensures that all processing has been completed, including the handling of asynchronous events for redirected standard output. You should use this overload after a call to the xtd::diagnostics::process::wait_for_exit(int32) overload when standard output has been redirected to asynchronous event handlers.
When an associated process exits (that is, when it is shut down by the operation system through a normal or abnormal termination), the system stores administrative information about the process and returns to the component that had called xtd::diagnostics::process::wait_for_exit(). The xtd::diagnostics::process component can then access the information, which includes the xtd::diagnostics::process::exit_time, by using the xtd::diagnostics::process::handle to the exited process.
Because the associated process has exited, the Handle property of the component no longer points to an existing process resource. Instead, the handle can be used only to access the operating system's information about the process resource. The system is aware of handles to exited processes that have not been released by xtd::diagnostics::process components, so it keeps the xtd::diagnostics::process::exit_time and xtd::diagnostics::process::handle information in memory until the xtd::diagnostics::process component specifically frees the resources. For this reason, any time you call xtd::diagnostics::process::start for a xtd::diagnostics::process instance, call xtd::diagnostics::process::close when the associated process has terminated and you no longer need any administrative information about it. xtd::diagnostics::process::close frees the memory allocated to the exited process.

◆ start() [2/4]

static process xtd::diagnostics::process::start ( const xtd::diagnostics::process_start_info start_info)
static

Starts the process resource that is specified by the parameter containing process start information (for example, the file name of the process to start) and associates the resource with a new xtd::diagnostics::process component.

Parameters
Thextd::diagnostics::process_start_ifo that contains the information that is used to start the process, including the file name and any command-line arguments.
Returns
A new xtd::diagnostics::process that is associated with the process resource. Note that a new process that's started alongside already running instances of the same process will be independent from the others. In addition, Start may return a xtd::diagnostics::process with its xtd::diagnostics::process::has_exited property already set to true. In this case, the started process may have activated an existing instance of itself and then exited.
Exceptions
xtd::invalid_operation_exceptionNo file name was specified in the startInfo parameter's xtd::diagnostics::process_start_info::file_name property.
Examples
Shows how to launch process.
#include <xtd/forms/application>
#include <xtd/forms/button>
#include <xtd/forms/button_images>
#include <xtd/forms/form>
#include <xtd/forms/vertical_layout_panel>
#include <xtd/diagnostics/process>
#include <xtd/invalid_operation_exception>
using namespace xtd;
using namespace xtd::diagnostics;
using namespace xtd::io;
using namespace xtd::forms;
class main_form : public form {
public:
main_form() {
text("Process form example");
controls().push_back(layout_panel);
client_size({350, 540});
layout_panel.controls().push_back_range({xtd_web_button, write_mail_button, open_home_folder_button, open_readme_txt_file_button, open_gammasoft_png_file_button, open_calculator_button});
layout_panel.dock(dock_style::fill);
layout_panel.control_layout_style(xtd_web_button, {size_type::auto_size, true});
layout_panel.control_layout_style(write_mail_button, {size_type::auto_size, true});
layout_panel.control_layout_style(open_home_folder_button, {size_type::auto_size, true});
layout_panel.control_layout_style(open_readme_txt_file_button, {size_type::auto_size, true});
layout_panel.control_layout_style(open_gammasoft_png_file_button, {size_type::auto_size, true});
layout_panel.control_layout_style(open_calculator_button, {size_type::auto_size, true});
xtd_web_button.image(button_images::from_name("text-html", drawing::size(64, 64)));
xtd_web_button.image_align(content_alignment::middle_left);
xtd_web_button.text("Open xtd website...");
xtd_web_button.click += [] {
process::start("https://gammasoft71.github.io/xtd");
};
write_mail_button.image(button_images::from_name("document-send", drawing::size(64, 64)));
write_mail_button.image_align(content_alignment::middle_left);
write_mail_button.text("Write mail...");
write_mail_button.click += [] {
process::start("mailto:gammasoft71@gmail.com?subject=Hi%20Gammasoft71&body=xtd%20is%20a%20great%20project.%0D%0A%20");
};
open_home_folder_button.image(button_images::from_name("folder-home", drawing::size(64, 64)));
open_home_folder_button.image_align(content_alignment::middle_left);
open_home_folder_button.text("Open home folder...");
open_home_folder_button.click += [] {
process::start(environment::get_folder_path(environment::special_folder::home));
};
open_readme_txt_file_button.image(button_images::from_name("text-x-generic", drawing::size(64, 64)));
open_readme_txt_file_button.image_align(content_alignment::middle_left);
open_readme_txt_file_button.text("Open \"readme.txt\" file...");
open_readme_txt_file_button.click += [] {
file::write_all_text(path::combine(path::get_temp_path(), "readme.txt"), "Tests open file \"readme.txt\" with xtd::diagnostics::process class.\n");
process::start(path::combine(path::get_temp_path(), "readme.txt"));
};
open_gammasoft_png_file_button.image(button_images::from_name("image-x-generic", drawing::size(64, 64)));
open_gammasoft_png_file_button.image_align(content_alignment::middle_left);
open_gammasoft_png_file_button.text("Open \"gammasoft.png\" file...");
open_gammasoft_png_file_button.click += [] {
images::from_name("gammasoft", drawing::size(512, 512)).save(path::combine(path::get_temp_path(), "gammasoft.png"));
process::start(process_start_info {"gammasoft.png"}.working_directory(path::get_temp_path()));
};
open_calculator_button.image(button_images::from_name("accessories-calculator", drawing::size(64, 64)));
open_calculator_button.image_align(content_alignment::middle_left);
open_calculator_button.text("Launch Calculator...");
open_calculator_button.click += [] {
if (environment::os_version().is_windows()) process::start(process_start_info {"calc"}.use_shell_execute(false));
else if (environment::os_version().is_macos()) process::start(process_start_info {"Calculator"});
else if (environment::os_version().is_linux()) process::start(process_start_info {"gnome-calculator"}.use_shell_execute(false));
else throw invalid_operation_exception("Calculator application unknown.");
};
}
private:
vertical_layout_panel layout_panel;
button xtd_web_button;
button write_mail_button;
button open_home_folder_button;
button open_readme_txt_file_button;
button open_gammasoft_png_file_button;
button open_calculator_button;
};
auto main() -> int {
}
const xtd::string & working_directory() const noexcept
When the xtd::diagnostics::process_start_info::use_shell_execute property is false,...
Stores an ordered pair of integers, which specify a height and width.
Definition size.h:31
static void run()
Begins running a standard application message loop on the current thread, without a form.
Represents a Windows button control.
Definition button.h:49
Represents a window or dialog box that makes up an application's user interface.
Definition form.h:54
Used to group collections of vertically aligned controls.
Definition vertical_layout_panel.h:31
The exception that is thrown when a method call is invalid for the object's current state.
Definition invalid_operation_exception.h:19
The xtd::forms namespace contains classes for creating Windows-based applications that take full adva...
Definition xtd_about_box.h:12
Remarks
Use this overload to start a process resource by specifying a xtd::diagnostics::process_start_info instance. The overload associates the resource with a new xtd::diagnostics::process object.
This overload lets you start a process without first creating a new xtd::diagnostics::process instance. Using this overload with a xtd::diagnostics::process_start_info parameter is an alternative to the explicit steps of creating a new xtd::diagnostics::process instance, setting its xtd::diagnostics::process::start_info properties, and calling Start for the xtd::diagnostics::process instance.
Using a xtd::diagnostics::process_start_info instance as the parameter lets you call xtd::diagnostics::process::start with the most control over what is passed into the call to start the process. If you need to pass only a file name or a file name and arguments, it is not necessary to create a new xtd::diagnostics::process_start_info instance, although that is an option. The only xtd::diagnostics::process::start_info property that must be set is the xtd::diagnostics::process_start_info::file_name property. The xtd::diagnostics::process_start_info::file_name property does not need to represent an executable file. It can be of any file type for which the extension has been associated with an application that is installed on the system. For example, the xtd::diagnostics::process_start_info::file_name property can have a .txt extension if you have associated text files with an editor, such as Notepad, or it can have a .doc extension if you have associated .doc files with a word processing tool, such as Microsoft Word.
Unlike the other overloads, the overload of xtd::diagnostics::process::start that has no parameters is not a static member. Use that overload when you have already created a xtd::diagnostics::process instance and specified start information (including the file name), and you want to start a process resource and associate it with the existing Process instance. Use one of the static overloads when you want to create a new Process component rather than start a process for an existing component. Both this overload and the overload that has no parameters allow you to specify the start information for the process resource by using a xtd::diagnostics::process_start_info instance.
If you have a path variable declared in your system using quotes, you must fully qualify that path when starting any process found in that location. Otherwise, the system will not find the path. For example, if c:\mypath is not in your path, and you add it using quotation marks: path = path%;"c:\mypath", you must fully qualify any process in c:\mypath when starting it.
Whenever you use xtd::diagnostics::process::start to start a process, you might need to close it or you risk losing system resources. Close processes using xtd::diagnostics::process::close_main_window or xtd::diagnostics::process::kill. You can check whether a process has already been closed by using its xtd::diagnostics::process::has_exited property.

◆ start() [3/4]

static process xtd::diagnostics::process::start ( const string file_name)
static

Starts a process resource by specifying the name of a document or application file and associates the resource with a new Process component.

Parameters
file_nameThe name of a document or application file to run in the process.
Returns
A new xtd::diagnostics::process that is associated with the process resource. Note that a new process that's started alongside already running instances of the same process will be independent from the others. In addition, Start may return a xtd::diagnostics::process with its xtd::diagnostics::process::has_exited property already set to true. In this case, the started process may have activated an existing instance of itself and then exited.
Exceptions
xtd::invalid_operation_exceptionNo file name was specified in the file_name parameter's xtd::diagnostics::process_start_info::file_name property.
Remarks
Use this overload to start a process resource by specifying its file name. The overload associates the resource with a new xtd::diagnostics::process object.
This overload lets you start a process without first creating a new xtd::diagnostics::process instance. The overload is an alternative to the explicit steps of creating a new xtd::diagnostics::process instance, setting the xtd::diagnostics::process_start_info::file_name member of the xtd::diagnostics::process::start_info property, and calling xtd::diagnostics::process::start for the xtd::diagnostics::process instance.
Starting a process by specifying its file name is similar to typing the information in the Run dialog box of the Windows Start menu. Therefore, the file name does not need to represent an executable file. It can be of any file type for which the extension has been associated with an application installed on the system. For example the file name can have a .txt extension if you have associated text files with an editor, such as Notepad, or it can have a .doc if you have associated .doc files with a word processing tool, such as Microsoft Word. Similarly, in the same way that the Run dialog box can accept an executable file name with or without the .exe extension, the .exe extension is optional in the fileName parameter. For example, you can set the fileName parameter to either "Notepad.exe" or "Notepad".
This overload does not allow command-line arguments for the process. If you need to specify one or more command-line arguments for the process, use the xtd::diagnostics::process::start(xtd::diagnostics::process_start_info) or xtd::diagnostics::process::start(string, string) overloads.
Unlike the other overloads, the overload of xtd::diagnostics::process::start that has no parameters is not a static member. Use that overload when you have already created a Process instance and specified start information (including the file name), and you want to start a process resource and associate it with the existing Process instance. Use one of the static overloads when you want to create a new xtd::diagnostics::process component rather than start a process for an existing component. Both this overload and the overload that has no parameters allow you to specify the file name of the process resource to start.
If you have a path variable declared in your system using quotes, you must fully qualify that path when starting any process found in that location. Otherwise, the system will not find the path. For example, if c:\mypath is not in your path, and you add it using quotation marks: path = path%;"c:\mypath", you must fully qualify any process in c:\mypath when starting it.
Whenever you use xtd::diagnostics::process::start to start a process, you might need to close it or you risk losing system resources. Close processes using xtd::diagnostics::process::close_main_window or xtd::diagnostics::process::kill. You can check whether a process has already been closed by using its xtd::diagnostics::process::has_exited property.

◆ start() [4/4]

static process xtd::diagnostics::process::start ( const string file_name,
const string arguments 
)
static

Starts a process resource by specifying the name of an application and a set of command-line arguments, and associates the resource with a new xtd::diagnostics::process component.

Parameters
file_nameThe name of a document or application file to run in the process.
argumentsCommand-line arguments to pass when starting the process.
Returns
A new xtd::diagnostics::process that is associated with the process resource. Note that a new process that's started alongside already running instances of the same process will be independent from the others. In addition, Start may return a xtd::diagnostics::process with its xtd::diagnostics::process::has_exited property already set to true. In this case, the started process may have activated an existing instance of itself and then exited.
Exceptions
xtd::invalid_operation_exceptionNo file name was specified in the file_name parameter's xtd::diagnostics::process_start_info::file_name property.
Remarks
Use this overload to start a process resource by specifying its file name and command-line arguments. The overload associates the resource with a new xtd::diagnostics::process object.
This overload lets you start a process without first creating a new xtd::diagnostics::process instance. The overload is an alternative to the explicit steps of creating a new xtd::diagnostics::process instance, setting the file_name and arguments members of the xtd::diagnostics::process_start_info property, and calling xtd::diagnostics::process::start for the xtd::diagnostics::process instance.
Starting a process by specifying its file name and arguments is similar to typing the file name and command-line arguments in the Run dialog box of the Windows Start menu. Therefore, the file name does not need to represent an executable file. It can be of any file type for which the extension has been associated with an application installed on the system. For example the file name can have a .txt extension if you have associated text files with an editor, such as Notepad, or it can have a .doc if you have associated .doc files with a word processing tool, such as Microsoft Word. Similarly, in the same way that the Run dialog box can accept an executable file name with or without the .exe extension, the .exe extension is optional in the file_name parameter. For example, you can set the file_name parameter to either "Notepad.exe" or "Notepad". If the file_name parameter represents an executable file, the arguments parameter might represent a file to act upon, such as the text file in Notepad.exe myfile.txt. If the file_name parameter represents a command (.cmd) file, the arguments parameter must include either a "/c" or "/k" argument to specify whether the command window exits or remains after completion.
Unlike the other overloads, the overload of xtd::diagnostics::process::start that has no parameters is not a static member. Use that overload when you have already created a xtd::diagnostics::process instance and specified start information (including the file name), and you want to start a process resource and associate it with the existing Process instance. Use one of the static overloads when you want to create a new Process component rather than start a process for an existing component. Both this overload and the overload that has no parameters allow you to specify the file name of the process resource to start and command-line arguments to pass.
If you have a path variable declared in your system using quotes, you must fully qualify that path when starting any process found in that location. Otherwise, the system will not find the path. For example, if c:\mypath is not in your path, and you add it using quotation marks: path = path%;"c:\mypath", you must fully qualify any process in c:\mypath when starting it.
Whenever you use xtd::diagnostics::process::start to start a process, you might need to close it or you risk losing system resources. Close processes using xtd::diagnostics::process::close_main_window or Kill. You can check whether a process has already been closed by using its xtd::diagnostics::process::has_exited property.

◆ on_exited()

virtual void xtd::diagnostics::process::on_exited ( )
protectedvirtual

Raises the xtd::diagnostics::process::exited event.

Remarks
xtd::diagnostics::process::on_exited is the API method that raises the xtd::diagnostics::process::exited event. Calling xtd::diagnostics::process::on_exited causes the xtd::diagnostics::process::exited event to occur and is the only way to raise the event using the Process component. xtd::diagnostics::process::on_exited is primarily used when deriving classes from the component.
As an alternative to xtd::diagnostics::process::xtd::diagnostics::process::on_eExited, you can write your own event handler. You create your own event handler delegate and your own event-handling method.

Member Data Documentation

◆ error_data_received

error_data_received_event xtd::diagnostics::process::error_data_received

Occurs when an application writes to its redirected xtd::diagnostics::process::standard_error stream.

Remarks
The xtd::diagnostics::process::error_data_received event indicates that the associated xtd::diagnostics::process has written a line that's terminated with a newline (carriage return (CR), line feed (LF), or CR+LF) to its redirected xtd::diagnostics::process::standard_error stream.
The event only occurs during asynchronous read operations on xtd::diagnostics::process::standard_error. To start asynchronous read operations, you must redirect the xtd::diagnostics::process::standard_error stream of a xtd::diagnostics::process, add your event handler to the xtd::diagnostics::process::error_data_received event, and call xtd::diagnostics::process::begin_error_read_line. Thereafter, the xtd::diagnostics::process::error_data_received event signals each time the process writes a line to the redirected xtd::diagnostics::process::standard_error stream, until the process exits or calls xtd::diagnostics::process::cancel_error_read.
Note
The application that is processing the asynchronous output should call the xtd::diagnostics::process::wait_forE_exit() method to ensure that the output buffer has been flushed. Note that specifying a timeout by using the xtd::diagnostics::process::wait_for_exit(int32) overload does not ensure the output buffer has been flushed.

◆ exited

exit_event xtd::diagnostics::process::exited

Occurs when a process exits.

Remarks
The exited event indicates that the associated process exited. This occurrence means either that the process terminated (aborted) or successfully closed. This event can occur only if the value of the EnableRaisingEvents property is true.
There are two ways of being notified when the associated process exits: synchronously and asynchronously. Synchronous notification means calling the xtd::diagnostics::process::wait_for_exit method to block the current thread until the process exits. Asynchronous notification uses the xtd::diagnostics::process::exited event, which allows the calling thread to continue execution in the meantime. In the latter case, xtd::diagnostics::process::enable_raising_events must be set to true for the calling application to receive the xtd::diagnostics::process::exited event.
When the operating system shuts down a process, it notifies all other processes that have registered handlers for the xtd::diagnostics::process::exited event. At this time, the handle of the process that just exited can be used to access some properties such as xtd::diagnostics::process::exit_time and xtd::diagnostics::process::has_exited that the operating system maintains until it releases that handle completely.
Note
Even if you have a handle to an exited process, you cannot call xtd::diagnostics::process::start again to reconnect to the same process. Calling xtd::diagnostics::process::start automatically releases the associated process and connects to a process with the same file but an entirely new xtd::diagnostics::process::handle.

◆ output_data_received

output_data_received_event xtd::diagnostics::process::output_data_received

Occurs each time an application writes a line to its redirected xtd::diagnostics::process::standard_output stream.

Remarks
The xtd::diagnostics::process::output_data_received event indicates that the associatedxtd::diagnostics::process has written a line that's terminated with a newline (carriage return (CR), line feed (LF), or CR+LF) to its redirected xtd::diagnostics::process::standard_output stream.
The event is enabled during asynchronous read operations on xtd::diagnostics::process::standard_output. To start asynchronous read operations, you must redirect the standard_output stream of a xtd::diagnostics::process, add your event handler to the xtd::diagnostics::process::Output_data_received event, and call xtd::diagnostics::process::begin_output_read_line. Thereafter, the xtd::diagnostics::process::output_dData_rReceived event signals each time the process writes a line to the redirected xtd::diagnostics::process::standard_output stream, until the process exits or calls xtd::diagnostics::process::cancel_output_read.
Note
The application that is processing the asynchronous output should call the WaitForExit method to ensure that the output buffer has been flushed.

The documentation for this class was generated from the following file: